RD-1 STANDARD LOCAL & NEIGHBORHOOD STREET SECTION
RD-3 STANDARD COLLECTOR STREET SECTIONS (TSP FIGURE 8-5a)
RD-4 STANDARD COLLECTOR STREET SECTIONS (TSP FIGURE 8-4)
RD-6 DOWNTOWN STREET STANDARDS - DOWNTOWN OVERLAY DISTRICT
RD-7 DOWNTOWN STREET STANDARDS - PEDESTRIAN "WOONERF" STREET SECTION
RD-8 DOWNTOWN STREET STANDARDS - DESIGN STANDARD NOTES
RD-11 STANDARD TANGENT CUL-DE-SAC
RD-12 STANDARD LOCAL STREET EYEBROW
RD-14 STANDARD LOOP TURNAROUND
RD-20 STANDARD RESIDENTIAL PAVEMENT SECTION
RD-22 STANDARD MONOLITHIC CURB AND GUTTER
RD-23 STANDARD REVERSE MOUNTABLE CURB AND GUTTER
RD-24 STANDARD MOUNTABLE CURB AND GUTTER
RD-26 STANDARD SIDEWALK DETAIL
RD-30 STANDARD CENTERLINE MONUMENTS
RD-31B STANDARD MONUMENT BOX FRAME
RD-31C STANDARD 8" MONUMENT WELL
RD-35 STANDARD STREET SIGN INSTALLATION DETAILS
RD-40 IRRIGATION SLEEVE STREET CROSSING DETAIL
RD-41 STANDARD RESIDENTIAL DRIVEWAY DETAIL
RD-42 STANDARD COMMERCIAL DRIVEWAY DETAIL
RD-43 STANDARD CURB RETURN & RAMP DETAIL
RD-44 DOUBLE CROSSING CURB RETURN & RAMP DETAIL
RD-45 ASPHALT PAVEMENT TRENCH RESTORATION
RD-46 STANDARD CONDUIT TRENCH BACKFILL AND SURFACE RESTORATION
RD-47 STANDARD PIPE TRENCH BACKFILL AND SURFACE RESTORATION
RD-50 SIDEWALK TRIP HAZARD DETAIL
RD-51 TYPE III STREET BARRICADE DETAIL
RD-53 CLEAR VISION AREA DETAIL
RD-56B PRIVATE ACCESS ROAD NOTES
RD-62 WIDENED SIDEWALK AT MAILBOX LOCATIONS
RD-63 PEDESTRIAN PATH & BIKEWAY SECTIONS
RD-64 MAINTENANCE ACCESS ROAD SECTIONS
RD-70 TYPICAL TRAFFIC CONTROL PLAN
RD-80 STANDARD SIDEWALK TREE WELL DETAIL
SS-2 PRECAST CONCRETE MANHOLE BASE
SS-3 PRECAST RUBBER GASKET MANHOLE
SS-6 MECHANICAL INSIDE DROP MANHOLE
SS-7 PARTITIONED INSIDE DROP MANHOLE
SS-9 INSIDE DROP MANHOLE W/ BOWL
SS-11 SUBURBAN AND STANDARD MANHOLE FRAME AND COVER - SANITARY
SS-13 WATERTIGHT MANHOLE FRAME AND COVER
SS-14 CONCRETE MANHOLE CLOSURE COLLAR
SS-16 LARGE PRECAST CONCRETE MANHOLE
SS-17 LARGE PRECAST CONCRETE MANHOLE - BASES
SS-18 LARGE PRECAST CONCRETE MANHOLE - TYPES
SS-19 LARGE PRECAST CONCRETE MANHOLE - BASE SLABS
SS-20 LARGE PRECAST CONCRETE MANHOLE - LONG BASE SECTION REINFORCED
SS-21 LARGE PRECAST CONCRETE MANHOLE - BASE SECTION REINFORCEMENT 108" & 120"
SS-22 LARGE PRECAST CONCRETE MANHOLE - TOP SLABS
SS-23 T-TOP MANHOLE WITH 48" RISER
SS-24 WATER QUALITY MANHOLE (MECHANICAL)
SS-25 WATER QUALITY MANHOLE (SNOUT) A
SS-26 WATER QUALITY MANHOLE (SNOUT) B
SS-27 FLOW CONTROL STRUCTURE DETAIL
SS-40 GUTTER & CURB INLET CATCH BASIN (CG-2)
SS-41 CUTTER & CURB INLET CATCH BASIN (CG-2) REINFORCEMENT
SS-42 CATCH BASIN FRAM AND GRATE (CG-2)
SS-43 INLET CATCH BASIN (CG-30)
SS-44 INLET CATCH BASIN (CG-48)
SS-45 CURB INLET MANHOLE (CG-48 M.H.)
SS-46 MODIFIED CURB INLET MANHOLE (MOD. CG-48 M.H.)
SS-47 TOP-CURB INLET MANHOLE AND MODIFIED CURB INLET MANHOLE (CG-48 M.H. AND MOD. CG-48 M.H.)
SS-50 DITCH INLET FRAME AND GRATE
SS-61 CLEANOUT FRAME AND COVER
SS-62 SIDE SEWER/SIDE STORM PIPELINE
SS-64 INDEXED PVD GASKETED SADDLE
SS-66 CONCRETE ENCASEMENT/CLOSURE COLLAR
SS-72 CREEK CROSSING RESTORATION
SS-81 WATER QUALITY SWALE CONSTRUCTION & MAINTENANCE NOTES
SS-82 OUTFALL CONTROL STRUCTURE
SS-84 CHAIN LINK FENCE AND GATE
SS-85 CONCRETE SPREADER DETAIL
SS-88 TREE PLANTING CONTAINER/BURLAPPED
SS-89 VEGETATED CORRIDOR SIGNAGE
SS-100 WASTEWATER PUMP STATION & FORCE MAIN DESIGN DATA SUMMARY TABLE (PAGE 1)
SS-101 WASTEWATER PUMP STATION & FORCE MAIN DESIGN DATA SUMMARY TABLE (PAGE 2)
SS-102 CONCEPTUAL SITE SCHEMATIC
SS-104 CHAIN LINK FENCE AND GATE
SS-106 FORCE MAIN PRESSURE GAUGE
SS-110 REDUCED PRESSURE BACKFLOW PREVENTER
SS-115 GENERAL TITLE SHEET - PUMP STATIONS
SS-116 ELECTRICAL ABBREVIATIONS & SYMBOLS - PUMP STATIONS (E00)
SS-117 ELECTRICAL ONE-LINE DIAGRAM - PUMP STATIONS (E01)
SS-118 ELECTRICAL INTERIOR ENCLOSURE - 01 - PUMP STATIONS (E02)
SS-119 ELECTRICAL INTERIOR ENCLOSURE - 02 - PUMP STATIONS (E03)
SS-120 ELECTRICAL CONTROL PANEL DETAIL - PUMP STATIONS (E04)
SS-121 ELECTRICAL SEQUENCE CONTROL DIAGRAM - PUMP STATIONS (E05)
SS-122 ELECTRICAL CONTROL PANEL DETAIL - PUMP STATIONS (E06)
SS-123 ELECTRICAL ENCLOSURE AND RAIN HOOD DETAIL - PUMP STATIONS (E07)
SS-124 ELECTRICAL INTRINSICALLY SAFE EXAMPLE - PUMP STATIONS (E08)
SS-125 ELECTRICAL WET WELL LEVEL DETAIL - PUMP STATIONS (E09)
SS-126 ELECTRICAL DISCONNECT AIR-GAP JUNCTION BOX DETAIL - PUMP STATIONS (E10)
SS-127 ELECTRICAL DETAILS - PUMP STATIONS (E11)
SS-140 SANITARY SEWER PERMANENT FLOW MONITOR DETAILS (MANHOLE CONDUIT INSTALLATION)
SS-145 CONDUIT TRENCH BACKFILL DETAILS
SS-154 MANHOLE VACUUM TEST FORM
SS-156 MANHOLE HYDROSTATIC TEST FORM
SS-160 AVERAGE VELOCITIES FOR ESTIMATING TRAVEL TIME FOR OVERLAND FLOWS
SS-161 HEADWATER DEPTH FOR CORRUGATED PIPE WITH INLET CONTROL
SS-162 HEADWATER DEPTH FOR SMOOTH INTERIOR PIPE CULVERTS WITH INLET CONTROL
SS-163 HEAD FOR CULVERTS (PIPE W/ "N" = 0.012), FLOWING FULL WITH OUTLET CONTROL
SS-164 HEAD FOR CULVERTS (PIPE W/ "N" = 0.024), FLOWING FULL WITH OUTLET CONTROL
SS-165 RATIONAL METHOD RAINFALL INTENSITIES
SS-166 24-HOUR RAINFALL DEPTHS
SS-167 DESIGN STORM DISTRIBUTION CHART
W-1 TYPICAL WATER VALVE LOCATION DETAIL
W-3 TYPICAL GATE VALVE SETTING DETAIL
W-4 BUTTERFLY VALVE SETTING DETAIL
W-7 SINGLE WATER SERVICE TYPICAL INSTALLATION
W-8 DUAL WATER SERVICE TYPICAL INSTALLATION
W-10 TRENCH BACKFILL ABOVE THE PIPE ZONE
W-15 SAMPLE STATION INSTALLATION
W-20 TYPICAL FIRE HYDRANT LOCATION DETAIL
W-21 FIRE HYDRANT STANDARD INSTALLATION
W-22 FIRE HYDRANT ON DEAD END LINE
W-33 2" STANDARD BLOWOFF (WITH FIELD-LOC GASKETS) USE WHERE LINE WILL CONTINUE
W-34 2" STANDARD BLOWOFF (WITH CONCRETE THRUST BLOCK) USE AT DEAD ENDS
W-35 RETROFIT 2" BLOWOFF OFF SIDE OF PIPE
W-40 VAULT LADDER INSTALLATION DETAIL
W-44 SUMP PUMP INSTALLATION ALTERNATIVE 2
W-50 1" COMBINATION AIR & VACUUM VALVE
W-51 2" COMBINATION AIR & VACUUM VALVE
W-60 1-1/2" & 2" METER INSTALLATION
W-61 3" MCT-II METER INSTALLATION BY CONTRACTOR
W-62 4" MCT-II METER INSTALLATION BY CONTRACTOR
W-64 6" X 3" MFM-MCT II METER INSTALLATION BY CONTRACTOR
W-65 8" X 4" MFM-MCT MFM-MCT METER INSTALLATION BY CONTRACTOR
W-67 10" X 6" MFM-MCT II METER INSTALLATION BY CONTRACTOR
W-70 TYPICAL BACKFLOW PREVENTERS FOR LAWN SPRINKLER SYSTEMS
W-71 DOUBLE CHECK VALVE ASSEMBLY (USE W/ FIRE SERVICE LINE)
W-73 1-1/2", 2", AND 2-1/2" DOUBLE CHECK INSTALLATION
W-74 DOUBLE CHECK VALVE ASSEMBLY CUSTOMER-OWNED (ABOVE GROUND) 2-1/2" - 10"
W-76 DOUBLE CHECK VALVE ASSEMBLY (USE W/ DOMESTIC SERVICE ONLY)
W-78 DOUBLE CHECK DETECTOR ASSEMBLY
W-79 DOUBLE CHECK DETECTOR ASSEMBLY CUSTOMER-OWNED (ABOVE GROUND) 3" TO 10"
W-80 REDUCED PRESSURE DETECTOR BACKFLOW ASSEMBLY CUSTOMER-OWNED (ABOVE GROUND) 2-1/2"
W-81 REDUCED PRESSURE DETECTOR BACKFLOW ASSEMBLY CUSTOMER-OWNED (ABV GROUND) IN VAULT 2-1/2" - 10"
W-84 REDUCED PRESSURE BACKFLOW ASSEMBLY CUSTOMER-OWNED (ABOVE GROUND) 3" TO 10"
W-85 1" REDUCED PRESSURE BACKFLOW PREVENTOR
W-86 1-1/2" & 2" REDUCED PRESSURE BACKFLOW DEVICE
W-87 REDUCED PRESSURE BACKFLOW ASSEMBLY CUSTOMER-OWNED (ABOVE GROUND) IN VAULT
W-88 REDUCED PRESSURE BACKFLOW ASSEMBLY DISCHARGE RATES
W-90 MINIMUM PROTECTION FOR FILLING TANKER TRUCKS
S-5 SUBDIVISION, COMMERCIAL SITE CONSTRUCTION HOUR NOTICE - SIGN
S-6 RESIDENTIAL SINGLE LOT CONSTRUCTION HOUR NOTICE - SIGN
ESC-1 MATTING CHANNEL INSTALLATION
ESC-2 MATTING SLOPE INSTALLATION
ESC-5 OUTLET PROTECTION - RIP RAP
ESC-6 OUTLET PROTECTION - STILLING BASIN
ESC-7 SURFACE ROUGHENING - CAT TRACKING
ESC-8 SURFACE ROUGHENING - STAIR STEPPING/GROOVING SLOPES
ESC-10 CHECK DAM - BIO FILTER BAG
ESC-14 TIRE WASH - MANUAL HOSE WASH
ESC-15 TIRE WASH - DRIVE THROUGH
ESC-18 WATTLES - SINGLE FAMILY APPLICATION
ESC-21 INLET PROTECTION - TYPE 1
ESC-22 INLET PROTECTION - TYPE 2
ESC-23 INLET PROTECTION - TYPE 3
ESC-24 INLET PROTECTION - TYPE 4
ESC-25 INLET PROTECTION - TYPE 5
ESC-26 INLET PROTECTION - TYPE 6
ESC-30 STANDARD EROSION CONTROL NOTES FOR SITES LESS THAN 1 ACRE
FO-1 CITY FIBER OPTIC GENERAL NOTES
FO-2 CITY FIBER OPTIC JUNCTION BOX DETAIL
FO-3 CITY FIBER OPTIC TRENCH DETAIL